sales office: 50 300 w factory road, addison il 60101 ? phone: (630) 628 - 9999 ? fax: (630) 628 - 9922 ? www.wabashtransformer.com split bobbin isolation transformer series: p24x - printed circuit mount, horizontal 12 pins ? power rating 2.4va to 30va ? single primary, 24v ? frequency 50/60hz ? series or parallel secondary ? dielectric strength C 1500 vrms ? insulation class b (130c) agency approvals: ? ul/cul 5085 - 2 recognized (file e47299) ? insulation file no. e95662 single primary indicates like polarity va rating part number dimensions (inches) mounting dimension wgt. lbs secondary series parallel l w h a b c d k m n p 2.4 p24x - 24 - 24 24vct @ 100ma 12v @ 0.200a 1.38 1.12 1.13 0.15 0.20 0.86 0.172 - 1.00 - - 0.230 20 p24x - 20 - 24 24vct @ 833ma 12v @ 1.670a 2.25 1.87 1.41 0.20 0.30 1.30 0.140 0.219 x 0.09* 1.69 1.50 1.88 0.780 30 p24x - 30 - 24 24vct @ 1.250a 12v @ 2.500a 2.25 1.87 1.79 0.20 0.30 1.30 0.140 0.219 x 0.09* 1.69 1.50 1.88 1.150 any application, any requirement, contact us for our custom designs * = slots primaries and secondaries are designed to be used simultaneously. that is, they must be used either series or parallel connected (as one winding). same applies to secondaries also.
|